008690F Raypak D-2 Power Vent Blower Adapter - Green
Part for Models : 206 | 207 | 266 | 267 | 268 | 336 | 366 | 406 | 407 | 408
D-2 Power Vent
Compatible for indoor or outdoor installation
For use with all Raypak Digital models, sizes 206A - 407A. The D-2 replaces the standard draft hood.
Certified
The D-2 Power Vent assembly is tested and certified to the latest edition of the American National Standard ANSI Z21.56 for pool heaters.
Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a 4” diameter exhaust connection and can be sidewall terminated.
Multi-Position
Using the supplied adjustable 90° elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). Or simply remove the elbow for vertical venting.
Dual-Voltage Induced-Draft Blower (120/240 VAC)
Factory set for 240 volts. Can be rewired in the field for 120v operation.
Safety at Its Best The D-2 Power Vent is equipped with a draft proving switch. This switch ensures that the blower is operating before operating your heater. It is also equipped with a solid state control that allows the blower to purge any residual gas buildup in the heater after the heater has shut down.
For use with all Raypak Digital models, sizes 206A - 407A. The D-2 replaces the standard draft hood.
Certified
The D-2 Power Vent assembly is tested and certified to the latest edition of the American National Standard ANSI Z21.56 for pool heaters.
Through-the-Wall Capable
The D-2 Power Vent assembly is a Category III mechanical draft venting system that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent. All sizes are capable of relieving flue gases up to a maximum of 100 equivalent feet of vent length. All models have a 4” diameter exhaust connection and can be sidewall terminated.
Multi-Position
Using the supplied adjustable 90° elbow, the flue gases may be discharged in any direction (see D-2 Power Vent manual for details). Or simply remove the elbow for vertical venting.
Dual-Voltage Induced-Draft Blower (120/240 VAC)
Factory set for 240 volts. Can be rewired in the field for 120v operation.
Safety at Its Best The D-2 Power Vent is equipped with a draft proving switch. This switch ensures that the blower is operating before operating your heater. It is also equipped with a solid state control that allows the blower to purge any residual gas buildup in the heater after the heater has shut down.
Brochure